We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
eu
Store
By selecting your region, you'll have access to the right catalogue
This will help estimate delivery schedule and fees
Discount code: ARM-2%
Discount code: ARM-4%
Discount code: ARM-5%
Your contribution to the Armuro Community is valuable for the other members, and we are grateful for it.
If you choose to proceed and delete the account, your data will be automatically anonymised and you will be logged out.
If you wish to delete your entire contribution to the Armuro Community, then please send an email to sales@armuro.com specifying your request and we will take care of it.
Actellic 50 EC, 100 ml is a powerful insecticide for use in storage applications against attacking insects. It provides reliable action for the protection of storage silos and warehouses.
Benefits:
- Acts by contact, ingestion, and fumigation;
- Organophosphorus compound;
- Does not affect seed quality;
- Acaricidal properties.
Action mode of Actellic 50 EC:
- It is a tool for insect control in storage applications:
- Provides fast effects and has a short waiting period;
- Kills insects and prevents their return in storage spaces;
- The strong fumigating action allows the control of pests in hard to reach places;
- It does not affect the quality of stored seeds.
Methods of application:
- seed storage areas should be treated using automatic systems (cold mist generators) before harvesting (late spring).
- the dosing of cold fog generators is done depending on the machine's specifications without exceeding the recommended dose.
For stored cereals:
- the seeds should be treated as soon as possible, as they are loaded into storage. Break time: 14 days from the treatment in the case of cereals treated on tape.
Recommendations:
- for best results, perform the treatment when the storage unit is empty.
- if drying is not performed, it can reduce the effectiveness of the treatment. - for best results in using this product, seed moisture should be kept below 15%.
- only qualified personnel is allowed to perform treatments using this product.
For storage:
Seed deposits should be treated with automatic systems (cold fog generators) prior to harvest (end of spring). Close the deposit between 24-48 hours. The dosing of cold fog generators is based on their type and specification without exceeding the recommended dose on the surface. For good results, treat when empty.
For stored cereals:
Seeds should be treated as soon as possible, as they are loaded onto the storage strip. Seeds showing slight moisture should be dried before treatment. If the drying is not done, it may reduce the effectiveness of the treatment by degrading the insecticide. For the best results in using this product, seed moisture should be kept below 15%. If the humidity is higher, the efficacy and duration of action of the product decrease.
Target area | Dangerous agent | Dosage |
Storage area (for automated application only) | Storage weevils | 1% (50-100 ml / sq.m.) |
Grain storage (for consumption) | Grain weevils | 10 ml commercial product/cereal (diluted in 1 l water) |
Please be sure to read, understand, and follow the full Conditions, Disclaimer, and Directions for Use. Use the appropriate personal safety equipment if required and when needed.
Stock Inquiry | No |
---|---|
Manufacturer | Syngenta |
Packaging | 100 ml |
Shelf life (years) | 3 |
Formulations | EC-Emulsifiable concentrate |
Active Substances | Pirimiphos-Methyl |
Active Substance Concentration | 500 g/litre |
Crops | Grain |
Bio Crops | Not suitable |
Mode of action | contact, ingestion |
Crop pests | weevil |
Dosage | 1 ml/t;50-100 ml/mp |
Application Type | Low pressure spray, ULV-Cold Fog |
Odor | strong irritant |
P210 | Keep away from heat/sparks/open flames/hot surfaces. – No smoking |
---|---|
P260 | Do not breathe dust/fume/gas/mist/vapours/spray |
P280 | Wear protective gloves/protective clothing/eye protection/face protection |
P301+P310 | IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician |
P305+P351+P338 | IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. , P309+P311 |
P310 | Immediately call a POISON CENTER or doctor/physician |
P331 | Do NOT induce vomiting |
P370+P378 | In case of fire: Use … for extinction |
P391 | Collect spillage |
P501 | Dispose of contents/container to … |
H226 | Flammable liquid and vapour |
H302 | Harmful if swallowed |
H304 | May be fatal if swallowed and enters airways |
H317 | May cause an allergic skin reaction |
H318 | Causes serious eye damage |
H335 | May cause respiratory irritation |
H336 | May cause drowsiness or dizziness |
H370 | Causes damage to organs <or state all organs affected, if known> <state route of exposure if it is conclusively proven that no other routes of exposure cause the hazard> |
H410 | Very toxic to aquatic life with long lasting effects. |